HomeMy WebLinkAboutUnion Pacific Railroad Company - Agreement - 12-20-2021SUPPAGR.DOC 980220
Form Approved, AVP-Law
SUPPLEMENTAL AGREEMENT
Audit: 283144
Folder: 03002-25
THIS SUPPLE NTAL AGREEMENT is entered into on the — dAy of
20 ,between UNION PACIFIC RAILROAD COMPANY ("Licensor") and
CITY OF FRESNO, a California municipal corporation, whose address is 2600 Fresno Street, Room
4019 Fresno, California 93721 ("Licensee").
RECITALS:
By instrument dated 8/14/2016, Licensor and Licensee, or their predecessors in interest,
entered into an agreement ("Basic Agreement"), identified as Audit No. 283144, at FRESNO,
CALIFORNIA.
AGREEMENT:
NOW, THEREFORE, IT IS AGREED by and between the parties hereto as follows:
Article 1. SUBSTITUTION OF PRINT.
The print dated May 04, 2020, attached hereto as Exhibit 'A', shall be and hereby is substituted
for the print dated August 14, 2016, attached to the Basic Agreement, and from and after the effective
date herein whenever the term Pipeline is used in the Basic Agreement, or any amendment or supplement
thereto (if any), such reference shall be deemed to refer to the Pipeline as shown on Exhibit 'A', hereto
attached.
Article 2. CONSENT TO WORK.
This Supplemental Agreement will serve as notification that the Railroad Company approves of
your intentions to install one (1) 16 inch DIP water pipe encased in a 34 inch Steel Pipeline Crossing in
accordance with Exhibit A.
Article 3. NOTICE OF COMMENCEMENT OF WORK / RAILROAD REPRESENTATIVE
/ SUPERVISION / FLAGGING / SAFETY.
If an emergency should arise requiring immediate attention, the Licensee shall provide as much
notice as practicable to Railroad, by calling the Response Management Communication Center at (888)
877-7267 before commencing any work. In all other situations, the Licensee shall notify the Railroad at
least ten (10) days (or such other time as the Railroad may allow) in advance of the commencement of
any work upon property of the Railroad in connection with the construction, maintenance, repair, renewal,
modification, reconstruction, relocation or removal of the Wireline. All such work shall be prosecuted
diligently to completion. The Licensee will coordinate its initial and any subsequent work with the
following employee of Railroad or his or her duly authorized representative (hereinafter "Railroad
Representative" or "Railroad Representative"):
Eduardo Soto
Manager of Track Maintenance
Work Phone: 559-246-4110
Email address: esoto@up.com
Eugene L. King
Manager of Signal Maintenance
Work phone: (402) 378-4143
Email address: elking@up.com
Article 4. EFFECTIVE DATE.
This Supplemental Agreement shall be effective as of May 04, 2020.
Article 5. AGREEMENT SUPPLEMENT.
Nothing in this Supplemental Agreement shall be construed as amending or modifying the Basic
Agreement unless specifically provided herein.
Article 6. ADMINISTRATIVE HANDLING CHARGE.
Upon execution and delivery of this Supplemental Agreement, the Licensee shall pay to the
Licensor an administrative handling charge of One Thousand DOLLARS ($1,000.00).
IN WITNESS WHEREOF, the parties have executed this Supplemental Agreement as of the day
and year first written.
UNION PACIFIC RAILROAD COMPANY
W.J1_Oor
Daniel C. Peters
Senior Manager - Real Estate
Union Pacific Railroad Company
Approved as to Form:
Douglas T. Sloan
City Actor e _
By:
eputy
Attest: (J
Briana Parra, �MC
Interi i lerk
By:
P-�,r�,1�D
CITY OF FRESNO
Public Wo De t
By:
Name Printed: L�
Title: A3t15-
Department of Pub] ic UtiIiti
By:
Name Printed: Xer�
Title:C-'71e4ASt0-\CG ,
EXHIBIT A - UPRR PROPERTY
PLACE ARROW INDICAIING NORTH
DIRECTION RELATIVE TO CROSSING 1,
40�
,?GjI NO SCALE
4541
fj C
D Madera `T�y
(NEAREST R.R. TOWN) G,I
FORM DR-0404-B
REV. 10-9-2012
www.uprr.com
ENCASED NON-FLAMMABLE
C MAIN TRACK
hn NessAve'CL
(DESCRIBE FIXED OBJECT)
(DISTANCE ALONG TRACK FROM SECTION LINE CROSSING)
(NOTE: THIS DIMENSION REOUIRED IN ALL CASES.
AT LOCATIONS NOT USING SECTIONS, DtS1
TO A LEGAL SURVEY LINE IS REDUIRED
RR• B Raw- ' 13.9
35_4 FT, �-� _ FT.
CL ML1
MIN. DIST
C
k
i
f
PIPEILINE CROSSING
W1-073
NOTE: ALL AVAILABLE DIMENSIONS MUST BE
FILLED IN TO PROCESS THIS APPLICATION. E Florence Ave
740 FT.
5 FT. k4.
T.
ZA= 71 0 08 ' 51 - D Fresno
(ANGLE (i>: CROSSU M1Gj � [NSARESi C. A, i0Al11v~
5O_7FT.
CL ML2 cacuND
I SURFACE
SuBGRADE
2 /
12.2 FT. SEAL CA91NG
SEAL CASING CASINO PIPE
/ I r CARRIER PIPE \
r�
/ 1 CS9.2F T. 63.81T.
8p rl<„ 60_7 FT.
7TTFT. 1
(CASING LENGTH NNEN MEASUR£0 ALONG PIPELINE.)
NOTE:
REFER TO AREMA VOLUME 1 PART 5 FOR REQUIREMENT RELATING TO PIPELINE CROSSINGS.
35.4' FT-
A)
IS PIPELINE CROSSING WITHIN DEDICATED STREET ? YES; A NO;
EXHIBIT "A99
B)
IF YES, NAME OF STREET
(FOR RAILROAD USE ONLY)
D)
DISTRIBUTION LINE X OR TRANSMISSION LINE
C)
CARRIER PIPE :
UNION PACIFIC RAILROAD CO.
COMMODITY TO BE CONVEYQ Water
OPERATING PRESSUR PSI
161I
�kP
Fresno
WALL THICKNESS ;AIAMETER ;MATERIAL
sueOlvlslONi
El
CASING PIPE :
Steel
M. P 206.86 E. S. 6001 +20
WALL THICKNESS 0.531" ;DIAMETER 34" ;MATER I AL
NOTE :CASING MUST HAVE 2" CLEARANCE BETWEEN GREATEST
ENCASED WATER CROSSING AT
OUTSIDE DIAMETER OF CARRIER PIPE AND INTERIOR DIAMETER OF
Fresno Fresno CA
PIPE. WHEN FURNISHING DIMENSIONS, GIVE OUTSIDE OF
CARRIER PIPE AND INSIDE OF CASING PIPE.
Nc Eti'clp-. :cv:- `1T Ei
F)
METHOD OF INSTALLING CASING PIPE UNDER TRACK(S):
City of Fresno
X DRY BORE AND JACK (WET BORE NOT PERMITTED)
TUNNEL ; OTHER
RR FILE NO- 3002-25 DATE 5/4/2020
G)
WILL CONSTRUCTION BE BY AN OUTSIDE CONTRACTOR? YES; NO;
H)
DISTANCE FROM CENTER LINE OF TRACK TO NEAR FACE OF jN1G �
w a R N ( IN c
JACKING PITS WHEN MEASURED AT RIGHT ANGLES TO TRACK
1)
APPLICANT HAS CONTACTED 1-800-336-9193f 130' MIN.)
IN ALL OCCASIONS, U. P. COMMUNICATIONS
DEPARTMENT MUST BE CONTACTED IN ADVANCE
U. P. COMMUNIyATION DEPARTMENT, AND HAS DETERMINED FIBER
OF ANY WORK TO DETERMINE EXISTENCE AND
OPTIC CABLE /X DOES ;-DOES NOT ; XIST IN L/ €INITY OF
2&20Q32fiQ5
LOCATION OF FIBER OPTIC CABLE.
PHONE: I-800-336-9193
WORK TO BE PERFORMED . TICKET NO.