HomeMy WebLinkAbout303.005 - Pump Operators Guide TRAINING AND EQUIPMENT MANUAL PUMPS 303.005 PUMP OPERATOR’S GUIDE EFFECTIVE: MARCH 2009 Current Revision Date: 07/17/20 Next Revision Date: 07/17/25 Author’s Name/Rank: Robert Camp, Battalion Chief Review Level: 1 Administrative Assistant: Leslie Oulashian, Management Analyst II Section 303.005 Page 1 of 15 PURPOSE The purpose of this procedure is to establish standard pump discharge pressures for the various hose deployment and nozzle configurations used by the Fresno Fire Department (FFD or Department). APPLICATION This procedure is to be applied by all personnel delivering water into hose lines. OPERATIONAL POLICY Incident Commanders shall be notified if pump pressures exceed 275 psi. OPERATIONAL GUIDELINE Pump operators should use the established pump discharge pressures for the identified hose deployment and nozzle configurations listed in this guide. PROCESS This section left intentionally blank. INFORMATION Refer to the guides listed below and located on Pages 3 – 15 of this policy: • Quick Reference Page (Most values are rounded.) • Preconnected Handlines Section 303.005 Page 2 of 15 • Apartment Lay Bundles • 2-1/2-Inch Handlines • Portable Monitor • Ladder Pipe And / Or Source Pumping Operations • Standpipe Operations • Sprinkler Systems • Foam Operations • Ammonia Diffusers Distributors • Bresnan Distributors • Piercing Nozzle • Relay Pumping/Friction Loss Tables • Formulas / Friction Losses • Water Availability Chart DEFINITIONS This section left intentionally blank. CROSS-REFERENCES No cross-references identified. Section 303.005 Page 3 of 15 Quick Reference Page (*) = Recommend a minimum of two (2) firefighters on the hoseline. (**) = Caution Firefighters! • Recommend a minimum of two firefighters on hoseline. • Any time wyed lines are in play, firefighters at the nozzles cannot be protected from significant nozzle reactions caused by opening and closing nozzles. PRECONNECTS Pump Discharge Pressure (PDP) Hose Lay GPM 1” Booster (SM-3 / TFT) 30 / 50 150 1 ½” Hotline (SM-10 / TFT) 100 / 150 148 / 183 *1 ¾” Preconnect (SM-20 / TFT) 155 / 200 151 / 171 APARTMENT LAY PDP Per 2 ½” Lengths Number of 1 ¾” Lines off of the Wye GPM 100 ft. 200 ft. 300 ft. *1 Bundle (100’ 1 ¾”, Wye, SM-20) 155 127 132 137 **2 Bundles 310 141 160 179 *1 Bundle (100’ 1 ¾”, Wye, TFT) 200 131 139 147 **2 Bundles 400 165 197 229 2 ½” HANDLINE PDP Hose Lay GPM 100 ft. 200 ft. 300 ft. 2 ½” Handline (SM-30 or TFT) 300 118 136 154 2 ½” Handline (TFT 1 3/16” Smooth Bore) 264 50 60 70 PORTABLE MONITOR PDP Hose Lay GPM 100 ft. 200 ft. 300 ft. 400 ft. 500 ft. LDH With SM-1000 or SM-1250 1000 / 1250 105 115 120 125 130 LADDER PIPE PDP Source Pump PDP to LDH Supplying Quint Provide 1250 GPM at 50 psi to Pump Inlet Section 303.005 Page 4 of 15 Preconnected Handlines 1-3/4-Inch Pre-Connect SM-20 Hose Lay GPM NP FL/100 Feet Total FL PDP 200’ of 1 ¾” 105 85 13 26 113 *155 93 29 58 *151 *170 95 35 70 *165 *212 100 54 108 *208 1-3/4-Inch Pre-Connect TFT Hose Lay GPM NP FL/100 Feet Total FL PDP 200’ *200 75 48 96 *171 (* ) = Recommend two firefighters on the hoseline and gate down lower pressure lines. STAND PIPE (SP) INCLUDING COMBO SYSTEMS PDP LDH to FDC: SP Floors up to 16th Maintain 175 psi Momentary Pressure Test at: 190 psi SPRINKLER SYSTEM PDP LDH to FDC Maintain 150 psi 1-1/2” Pre-Connect SM-10F, TFT Hose Lay GPM NP FL/100 Feet Total FL PDP 200’ of 1-1/2“ SM-10 100 100 24 48 148 TFT 150 75 54 108 183 Section 303.005 Page 5 of 15 Apartment Lay Bundles Apartment Lay: 100’ of 1-3/4”, A Wye, 2-1/2” Supply SM-20F Nozzles # of 1-3/4” Lines Total GPM FL Wye NP FL 1-3/4” FL 2-1/2” PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ *1 212 0 100 53 9 162 171 180 189 198 *1 155 0 93 29 5 127 132 137 142 147 **2 424 10 100 53 36 199 235 271 **2 310 0 93 29 19 141 160 179 198 217 Apartment Lay: 100’ of 1-3/4”, A Wye, 2-1/2” Supply TFT Nozzles # of 1-3/4” Lines Total GPM FL Wye NP FL 1-3/4” FL 2-1/2” PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP / 500’ *1 200 0 75 48 8 131 139 147 155 163 **2 400 10 75 48 32 165 197 229 261 (*) = Recommend a minimum of two firefighters on the hoseline. (**) = Caution Firefighters! • Recommend a minimum of two firefighters on hoseline. • Any time wyed lines are in play, firefighters at the nozzles cannot be protected from significant nozzle reactions caused by opening and closing nozzles. Section 303.005 Page 6 of 15 2-1/2-Inch Handlines 2-1/2-Inch Handline Elkhart SM-30 or TFT H2TO GPM NP FL/100’ PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ 225 90 10 100 110 120 130 140 250 94 12 106 118 130 142 154 300 100 18 118 136 154 172 190 2-1/2-Inch Handline TFT 1 3/16” Smooth Bore GPM NP FL/100’ PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ 264 40 10 50 60 70 80 90 *324 60 10 70 80 90 100 110 (*) = Recommend for a defensive operation such as a packing house loop. Section 303.005 Page 7 of 15 Portable Monitor 5-Inch Supply Line (SM-1000) GPM NP Appliance FL FL Per 100” PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ PDP/ 600’ 1000 75 25 4.1 104 108 112 116 121 125 500 70 25 1.1 96 97 98 99 101 102 5-Inch Supply Line (SM-1250) GPM NP Appliance FL FL Per 100” PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ PDP/ 600’ 1250 75 25 6.25 106 113 119 125 131 138 655 60 25 1.7 87 88 90 92 94 95 Note: FFD may have the following alternate M/S tips in service. PDP should be adjusted as follows: • SM 100 (pre 2007) 1000 GPM at 100 PSI nozzle pressure o Add 25 PSI to above prescribed PDP • TFT 1250 GPM at 100 PSI nozzle pressure (Reserve Apparatus). o Add 25 PSI to above prescribed PDP • Akron 1250 GPM at 80 PSI nozzle pressure (North Central Apparatus) o Add 5 PSI to above prescribed PDP 5-Inch Supply Line (Solid Stream) Nozzle Tip GPM NP Appliance FL FL/ 100’ PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ PDP/ 600’ 1-1/2- Inch 600 80 25 1.5 107 108 110 111 113 114 1-3/4- Inch 800 80 25 2.6 108 110 113 115 118 121 2-Inch 1000 80 25 4.1 109 113 117 121 126 130 Section 303.005 Page 8 of 15 Ladder Pipe And / Or Source Pumping Operations • The objective of ladder pipe operations is to flow the rated nozzle GPM. • Flow meters frequently become out of calibration or can fail completely. Although increasing PDP until flow meter(s) read the appropriate GPM is generally acceptable, the following charts shall give guidance if flow meter accuracy is in question. • The pump on quints should be used whenever possible. Note: PDP assumes full nozzle elevation at 100’. As necessary, subtract 5 psi per estimated 10 feet of nozzle elevation below 100’ when aerial is not at the highest extension and / or angle of elevation. Ladder Pipe (Quint Pump PDP) Nozzle GPM NP Ladder Pipe FL 100’ Elevation PDP Fog SM-1250E 1250 75 80 50 205 Fog SM-1500E 1500 70 80 50 200 Fog Akron 2000 2000 80 80 50 210 2” Solid Stream 1250 110 80 50 240 Source Pumping LDH to Ladder Pipe Intake (Quint Pump Not Used) Nozzle GPM NP App. FL 100’ Elevation FL Per 100’ PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ Fog 1250 75 80 50 6 211 217 223 229 235 Fog 1500 70 80 50 9 209 218 227 236 245 Fog 2000 80 80 50 16 226 242 258 274 1-3/8” 500 80 80 50 1 211 212 213 214 215 1-1/2” 600 80 80 50 1.5 212 213 215 216 218 1-3/4” 800 80 80 50 2.6 213 215 218 220 223 2” 1000 80 80 50 4 214 218 222 226 230 Section 303.005 Page 9 of 15 Source Pumping LDH to Supply a Pumper or Quint GPM LDH FL per 100’ Maintain Residual PSI Pump Intake PDP/ 400’ PDP/ 500’ PDP/ 600’ PDP/ 700’ PDP/ 800’ PDP/ 900’ PDP/ 1000’ 1500 9 50 86 95 104 113 122 131 140 1250 6 50 74 80 86 92 98 104 110 1000 4 50 66 70 74 78 82 86 90 Standpipe Operations • FDC Supply Pumper: o Test Pressure: 190 PSI. o Operating Pressure: Maintain 175 psi at all times.  Exception: 2220 Tulare (Old Del Web): Maintain 210 PSI for fires above the 16th floor. o Do not exceed 200 psi in dry or combination standpipe systems.  Exception: 2220 Tulare (Old Del Web) The Combination system on this building is tested at approximately 225 psi. • Standpipe Control Valve: o Target pressure at the SP discharge while one line is flowing:  Begin with 95 PSI.  Add 5 PSI per floor that hoselines are deployed to above the discharge.  Add 15 PSI per 50’ section of 2-1/2” needed to place the wye at the base of a stairwell when SP discharges are not in the stairwell. Sprinkler Systems • Attempt to maintain 150 psi at all times. Section 303.005 Page 10 of 15 Exception: o Super Block: West side of Van Ness, between Fresno and Tulare. o Super Block FDC’s must be pumped at a maximum of 75 PSI if the system’s fire pump is operating. If the system’s fire pump is not operating and sprinklers are flowing, lock-out / tag-out the pump electric power source and pump the FDC at 150 PSI. • Five-inch hose is always preferable. Foam Operations Foam Fuel Type Foam % Class A (Silvex Plus or Phos-Chek 881) Ordinary Combustibles .5 to 1% Class B AFFF Hydrocarbons (Gasoline, Oil) 3% Class B AFFF Polar Solvents (Alcohol, Acetone) 6% • Elkhart In-Line Eductor: o Objective is 100 GPM and 200 psi at the eductor inlet. Nozzle Length SM-10 (1 ½-inch Hose) 150 feet TFT (1 ½-inch Hose) Up to 200 feet SM-20 (1 ¾-inch Hose) Up to 400 feet TFT (1 ¾-inch Hose) Up to 500 feet o If using 2 ½ inch to supply eductor, attach Camcone or Big Boy shutoff. Elkhart In-Line Eductor Pressure at Eductor Inlet GPM Friction Loss in 2-1/2-Inch Hose PDP/ 100’ PDP/ 200’ PDP/ 300’ PDP/ 400’ PDP/ 500’ PDP/ 600’ 200 100 2 202 204 206 208 210 212 Section 303.005 Page 11 of 15 Ammonia Diffusers Distributors 2-1/2-Inch Inlet Connection 500 gpm Pressure at Inlet = 9 psi Friction Loss in 2-1/2-Inch Hose = 50 psi/100 Feet Length of Lay Hose Friction Loss PDP 100 Feet 50 59 200 Feet 100 109 300 Feet 150 159 400 Feet 200 209 500 Feet 250 259 1-1/2-Inch Inlet Connection 500 gpm Pressure at Inlet = 56 psi Friction Loss in 2-1/2-Inch Hose = 50 psi/100 Feet Length of Lay Hose Friction Loss PDP 100 Feet 50 106 200 Feet 100 156 300 Feet 150 206 400 Feet 200 256 Section 303.005 Page 12 of 15 Bresnan Distributors 2-1/2” Elkhart 193-9 (495 GPM) Length of Lay NP Hose FL PDP 100’ 100 50 150 200’ 100 200 300’ 150 250 400’ 200 300 1-1/2” Elkhart 193-6 / 1-1/2” Hose (140 GPM) 1-1/2” Elkhart 193-6 / 1-3/4” Hose (140 GPM) Length of Lay NP Hose FL PDP Length OF Lay NP Hose FL PDP 100’ 100 47 147 100’ 100 24 124 200’ 94 194 200’ 48 148 300’ 141 241 300’ 72 172 400’ 96 196 500’ 120 220 Section 303.005 Page 13 of 15 Piercing Nozzle PDP for 1-3/4” GPM FL PDP/ 200’ PDP/ 300’ PDP/ 300’ PDP/ 400’ 150 23 133 156 179 202 200 40 240 Relay Pumping/Friction Loss Tables • 1,000 gpm. • One 4-inch or 5-inch line. • Start from source. • Space engines maximum 1,000 feet apart. • 50 psi at inlet; minimum 20 psi. • Adjust pressures according to need at fire pumper. Friction Loss 5-Inch Hose gpm FL/100 Feet gpm FL/100 Feet gpm FL/100 Feet 400 0.64 750 2.4 1,100 4.8 450 0.81 800 2.6 1,150 5.3 500 1.1 850 2.9 1,250 6.3 550 1.2 900 3.0 1,300 6.8 600 1.5 950 3.6 1,400 7.8 650 1.7 1,000 4.1 1,500 9.0 700 1.9 1,050 4.4 1,750 12.3 Section 303.005 Page 14 of 15 Formulas / Friction Losses Determining PDP: PDP = NP + FL + EP + APL NP = Nozzle Pressure FL = Friction Loss in Hose EP = Elevation Pressure Loss or Gain APL = Appliance Friction Loss Friction Loss Formula for Hose: FL = C x Q² x L C = Coefficient Q = Quantity of Flow for every 100 gpm L = Length of Hose Lay for every 100 feet Friction Loss Coefficients: 1” 150 1 ½” 24 1 ¾” 12 2” 6 2 ½” 2 5” 0.04 Friction Loss for Appliances: Wye, Siamese: 10 (For flows ≥ 350 GPM) Standpipe: 10 (For the FDC) Deck Pipes and Portable Monitors: 25 100’ Ladder Pipe Including M/S Appliance: 80 Section 303.005 Page 15 of 15 Water Availability Chart (For calculating available water from a hydrant for “Like Lines” per IFSTA) Percent Method: 0-10 Percent = Three times the amount flowing. 11-15 Percent = Two times the amount flowing. 16-25 Percent = One time the amount flowing. 26 Percent or more = More water may be available, but not more than the current amount flowing. Static Reading 10 Percent DROP 15 Percent DROP 25 Percent DROP 40 36 34 30 45 40 38 34 50 45 43 38 55 49 47 41 60 54 51 45 65 58 55 49 70 63 59 53 75 68 64 56