SECTION 302.001 ELKHART NOZZLES
PURPOSE
The purpose of this procedure is to familiarize Fresno Fire Department (FFD or
Department) members with the operational principles and technical data necessary to
properly use the Elkhart Select-O-Matic (SM) series nozzles.
APPLICATION
This section intentionally left blank.
OPERATIONAL POLICY
This section intentionally left blank.
OPERATIONAL GUIDELINE
Members operating the Elkhart series nozzles should be familiar with the basic operations
and flow capabilities of each nozzle. For recommended pump discharge pressures, refer
to the Training and Equipment Manual, Section 303.005, Pump Operator’s Guide.
PROCESS
1. Nozzle Operation: The horseshoe bale operates the ball shutoff portion
of all Select-O-Matic and Chief XD handline nozzles. To open the nozzle,
pull back on the bale. To close the nozzle, push forward on the bale.
2. Stream Pattern Selection: The tip of the Select-O-Matic and Chief XD
nozzles are protected by a heavy-duty urethane bumper that controls
the stream pattern selection and the flush mechanism if available. To
change from fog to straight stream, rotate the tip to the right. To change
to fog or flush, rotate the tip to the left. Master stream nozzles have
large control handles to assist with stream pattern adjustment.
3. Flushing the Nozzle: To flush the nozzle of small debris, turn the nozzle
tip all the way to the left (past wide fog). The flush setting is not intended
for firefighting use.
Effective Date: October 2007 Robert Camp, Battalion Chief
Current Revision Date: 12/31/2025 Section 302.001
Next Revision (1) Date: 12/31/2028 Page 2 of 3
INFORMATION
1. Chief XD Series Tips:
• Mid-Range 1 ½ inch Rigid Inlet
o For use with 1 ½ inch Chief XD shutoff.
o Fixed flow handline rated at 160 GPM at 50 psi nozzle
pressure.
2. Select-O-Matic Series Nozzles:
• TSM-30:
o For use with a separate valve on 2 ½ inch hose.
o Rated at 300 GPM at 100 psi nozzle pressure.
o Automatically delivers an effective stream or pattern with
flows ranging from 75 to 325 GPM at nozzle pressures
above 60 psi.
• SM-100:
o For use with master-stream appliances.
o Rated at 1,000 GPM at 100 psi nozzle pressure.
o Automatically delivers an effective stream or pattern with
flows ranging from 300 to 1,000 GPM at nozzle pressures
above 85 psi.
• SM-1000:
o For use with master-stream appliances.
o Rated at 1,000 GPM at 75 psi nozzle pressure.
o Automatically delivers an effective stream or pattern with
flows ranging from 300 to 1,000 GPM.
Effective Date: October 2007 Robert Camp, Battalion Chief
Current Revision Date: 12/31/2025 Section 302.001
Next Revision (1) Date: 12/31/2028 Page 3 of 3
• SM-1250E:
o For use with aerial master-stream appliances.+
o Rated at 1,250 GPM at 75 psi nozzle pressure.
o Automatically delivers an effective stream or pattern with
flows ranging from 350 to 1,250 GPM.
• SM-1500E:
o For use with aerial master-stream appliances.
o Rated at 1,500 GPM at 70 psi nozzle pressure.
o Automatically delivers an effective stream or pattern with
flows ranging from 500 to 1,500 GPM.
For all Elkhart nozzles, the letter at the end of the model number designates the following:
• “E” = has electric controls.
• “F” = has a “flush” capability.
• “G” = has a pistol grip.
DEFINITIONS