Loading...
HomeMy WebLinkAbout315.014 - Drafting Operation, Reverse Lay TRAINING AND EQUIPMENT MANUAL COMPANY PERFORMANCE EVOLUTIONS (CPEs) 315.014 DRAFTING OPERATION, REVERSE LAY EFFECTIVE: JUNE 2011 Current Revision Date: 12/19/18 Next Revision Date: 12/19/20 Author’s Name/Rank: Christian Palmer, Captain Review Level: 1 PURPOSE Promote training for, and assist in measuring fire ground effectiveness of, crews performing a drafting evolution. APPLICATION All extended fire suppression operations require a reliable water supply. In areas where fire hydrants are scarce, a drafting operation can be used. Crews need to be able to identify the location of, and quickly secure a water supply from, a static water source. OPERATIONAL POLICY This section intentionally left blank. OPERATIONAL GUIDELINE All hose lines should be completely deployed from hosebeds prior to charging. Hose lines should not have kinks which would reduce the effectiveness of water delivery. All nozzles should operate at appropriate pressures to achieve stated gpm. Members operating near the edge of a static water source should not wear turnout gear and should have on a Personal Floatation Device. Section 315.014 Page 1 of 3 PROCESS Time begins when apparatus stops at fire scene and ends when water is flowing at required pressure and supply line has been established. Second apparatus waits 30 seconds after start time before responding to simulate difference in response time. Equipment Needed: Two engine companies with members in full PPE, including SCBA for handline crew. Task: Deploy and flow two pre-connected hand lines from the pumping apparatus. Pumping apparatus to be supplied by a reverse lay from a second apparatus drafting from a static source 300 feet away. Performance Outcome: A minimum of 300 gpm flowing from two pre-connected hand lines supplied by a second appartus drfafting from a static source. Company Directive: Deploy two pre-connected handlines from the pumping apparatus. Second apparatus to reverse lay from the pumping apparatus to a static water source and perform a drafting operation. Second apparatus waits 30 seconds after time has strarted before beinging their task. The task should be completed within 6 minutes. 300' LDH Static Water Source 200' 200' Handlines INFORMATION This section intentionally left blank. DEFINITIONS This section intentionally left blank. Handlines 300 gpm Section 315.009 Page 2 of 3 CROSS REFERENCES NFPA 1410, Training for Initial Emergency Scene Operations, Chapter 6 Training and Equipment Manual, Section 202.014d, Water Rescue Section 301.004, Supply lines and water supply Section 301.005, Advancing and operating hose lines Section 303.005, Pump operator’s guide IFSTA Pumping Apparatus Driver/Operator Handbook Section 315.009 Page 3 of 3