HomeMy WebLinkAbout313.009a - Supplying 2 ½-Inch Handlines (IPE)
TRAINING AND EQUIPMENT MANUAL
DRIVER / OPERATOR SKILLS
313.009a SUPPLYING 2-1/2-INCH HANDLINES
INDIVIDUAL PERFORMANCE EVOLUTION
EFFECTIVE: MARCH 2016
Current Revision Date: 10/22/21 Next Revision Date: 10/22/23
Author’s Name/Rank: Robert J. Garcia, Engineer Review Level: 2
Administrative Support: Tammy Williams
Management Analyst II
ADA
PURPOSE
To measure a pump operator’s ability to quickly and efficiently provide adequate hose
line pressure(s) to 2 ½” handlines.
APPLICATION
Individual performance evolutions (IPE) are used to document skill level performance.
OPERATIONAL POLICY
This section intentionally left blank.
OPERATIONAL GUIDELINE
This section intentionally left blank.
PROCESS
Instructions to the Operator:
The operator is given a simulated scenario to flow a 2-1/2” handline.
Equipment and Personnel Requirements:
Operator wearing helmet and gloves.
1 FFD pumping apparatus.
1 2-1/2” hose and nozzle.
1 Firefighter wearing helmet and gloves.
Section 313.009a
Page 1 of 4
1 Hydrant
Instructions to the Evaluator:
The evaluator should stop any evolution when unsafe acts or conditions occur.
Evolution:
A recommendation for improvement is indicated by a checkmark in a box with
standard text (non-bold font).
A need for improvement and scheduling of an evolution is indicated by a checkmark
in a box with standard text in bold font.
INFORMATION
This section intentionally left blank.
DEFINITIONS
This section intentionally left blank.
CROSS REFERENCES
Training and Equipment Manual
Section 303.005, Pump Operator Guide
Section 313.005a, Standard Pump Operation (IPE)
Section 313.007a, Change-over from Tank to Hydrant (IPE)
Section 313.009a
Page 2 of 4
I I I I I
TRAINING AND EQUIPMENT MANUAL
DRIVER / OPERATOR SKILLS
313.009a SUPPLYING 2-1/2-INCH HANDLINES
INDIVIDUAL PERFORMANCE EVOLUTION
EFFECTIVE: APRIL 2007
Name: ________________________
ID #: ________________________
Date: ________________________
Supplying 2-1/2-Inch Handlines
No. Task Steps 1st
Attempt
2nd
Attempt
1. Prepare pumper to pump water. (Refer to IPE Section
313.005a)
2. Secure a supply. (Refer to IPE Section 313.007a)
3. Ensure ample hose has been flaked out for advancement.
4. Make 2-1/2” connection to an appropriate discharge.
5. Remove significant kinks.
6. Check for visual or audible call for water from firefighter.
7. Call “water coming” to firefighter(s).
8. Locate appropriate discharge valve handle/controller and
associated discharge gauge.
9. Charge hose line at a controlled rate.
10. Set appropriate discharge pressure. (Refer to Section
303.005)
10a. Observe hose line specific discharge gauge.
11. Properly Set Pump Boss/Pressure Control Valve
12. Never allow discharge pressures to fall below or exceed
target PDP by more than 30 psi.
13. Check undercarriage for leaks.
14. Assess water supply / update command, as needed.
15. Observe the following: Water Tank Level, Engine Temp.,
Oil Pressure.
16. Note abnormal noises or concerns.
17. Additional notes:
Critical Errors:
1. Perform an unsafe act which could result in injury to
himself / herself, crew, or the public.
2. Perform an act which did or could have damaged
equipment.
Section 313.009a
Page 3 of 4
*10-minute rest period minimum before retest attempt
Overall Grade: Pass Fail
Evaluator #1 Signature
Evaluator #1 Signature
Candidate Signature
Retest Evaluator #1 Signature
Retest Evaluator #1 Signature
Candidate Signature
Start Time: End Time:
Employee ID #
Employee ID #
Employee ID #
Employee ID #
Date
Date
Date
Date
Date
Date
Evaluator Comments:
Candidate Comments:
Section 313.009a